Split DC EV Charger CSD R3
600kW–960kW Split DC EV Charger | High-Power Liquid-Cooled EV Charging System for Commercial Fleets
Ultra-High Power Output
Modular & Scalable Design
Multi-Gun Charging Capability
Advanced Cooling System
Smart User Interface
Multiple Billing Options
Full Communication & Control
High Safety & Reliability
Industrial-Grade Build
CEVC 600KW–960KW Split DC charging pile—CE | |||||||
---|---|---|---|---|---|---|---|
Power | 600KW | 720KW | 800KW | 960KW | |||
Module | 30KW | 30KW | 40KW | 40KW | |||
Port | 10 | 12 | 10 | 12 | |||
machine | Size (W×D×H) | Host machine: 1550mm×1100mm×2000mm | Defense Lv. | IP54 (outdoors) | |||
Terminal: 400mm×290mm×1500mm | Cooling | Forced air cooling | |||||
weight | Host machine (modular): 960KW about (935 kg) | cable length | 3m, 5m (optional) | ||||
Terminal (Gun with charge): about (75 kg) / pc | Output terminal | 1 to 10, 12 (optional) | |||||
Installation type | Floor type | ||||||
input | AC input voltage | AC400V±10% (3P+N+PE) | frequency | 45Hz∼65Hz | |||
Phase line | L1, L2, L3, N, PE | Power factor | ≥0.98 | ||||
Current THD | <5% | ||||||
exportation | Rated output power | 600KW, 720KW, 800KW, 960KW (optional) | Single gun output power | 250KW Max | |||
Output voltage | DC200V∼1000V | efficiency | ≥95% | ||||
Single gun output current | 250A Max | measure | DC meter measurement | ||||
environment | Operating temp | -30°C to 50°C (50°C to 70°C Derated output) | humidness | 5%∼95% (No condensation) | |||
Storage temp | -40°C to +70°C | Altitude | ≤2000 m (Full load output) | ||||
screen | Display screen | 7 inch touch screen | Payment method | Plug and charge swipe card, scan code (optional) |
|||
scram | Press to stop | Billing mode | Automatic charging, fixed power, fixed amount fixed time (optional) |
||||
secure | Charging interface standard | IEC 62196-3 TYPE2 | Pile and car | PLC mode, in line with DIN70121/ISO1511 standard, configure OCPP1.6 protocol | |||
communication | |||||||
Charging connection mode | GB/T18487 | Communication mode | Ethernet, 4G (optional) | ||||
Protection function | Grounding, over-current, over-voltage, over-temperature, short circuit, insulation, polarity, surge, emergency stop, access control, abnormal connection, alarm, etc. |
The CSD-R3 is a high-capacity split-type DC EV charger engineered for ultra-fast, multi-vehicle charging in commercial and industrial applications. Available in 600kW, 720kW, 800kW, and 960kW configurations, this system delivers up to 480kW per outlet (optional), making it ideal for electric buses, trucks, and high-demand fleet operations.
The system features a modular power cabinet with air/liquid cooling, multiple gun ports (10, 12 optional), and advanced load balancing. The 7-inch touchscreen interface supports multiple user modes, including plug & charge, swipe card, and scan-to-charge via QR code. Integrated smart billing supports per kWh, fixed time, and fixed amount modes.
With IP54 protection, Ethernet and 4G communication, and full compliance with DIN70121/ISO15118 and OCPP1.6 protocols, the CSD-R3 ensures stable, smart charging for next-gen EV infrastructure. It also includes comprehensive safety protections such as overvoltage, overcurrent, insulation monitoring, and emergency stop.
-
Ultra-High Power Output
Available in 600kW, 720kW, 800kW, and 960kW configurations with up to 480kW output per terminal, ideal for heavy-duty EV fleets.
-
Modular & Scalable Design
Power cabinet supports 30kW or 40kW power modules, enabling flexible system scaling and easy maintenance.
-
Multi-Gun Charging Capability
Supports up to 12 charging terminals with simultaneous output, enabling efficient multi-vehicle charging.
-
Advanced Cooling System
Air or optional liquid cooling ensures safe operation under full load and extends system lifespan.
-
Smart User Interface
7-inch touchscreen with support for plug & charge, RFID card swipe, and QR scan-to-charge modes.
-
Multiple Billing Options
Supports per kWh billing, fixed price, fixed time, or user-defined billing logic.
-
Full Communication & Control
Ethernet and optional 4G communication; supports OCPP 1.6J and conforms to DIN70121/ISO15118.
-
High Safety & Reliability
Offers complete protection suite including overvoltage, overcurrent, overheating, grounding, short circuit, insulation, and emergency stop.
-
Industrial-Grade Build
IP54-rated for outdoor use with IK10-level enclosure durability and operation up to 2000m altitude.
The CSD-R3 split DC fast charging system is ideal for large-scale, high-demand EV charging environments, including:
-
Electric Bus & Truck Depots
Delivers ultra-fast overnight or turnaround charging for public transit, logistics, and long-haul commercial fleets.
-
Fleet Charging Yards
Perfect for taxi, ride-hailing, and commercial fleet operators requiring multiple fast-charging ports.
-
Highway Charging Hubs
Enables ultra-fast long-distance travel support at major highway rest stops or intercity EV corridors.
-
EV Charging Stations
Central power cabinets with distributed terminals help expand capacity in public or semi-public charging infrastructure.
-
Smart Energy Projects & Microgrids
Integrates with energy management systems for efficient load distribution and grid-friendly operation.
-
OEM & Industrial Use
Suitable for automotive manufacturers, EV testing centers, and industrial users requiring high-output charging for R&D or production support.